ULTRA FLO® · Spiral rib storm sewer

ULTRA FLO®
Smooth flow.
Flexible steel strength.

Specify a spiral rib storm sewer with a smooth interior and exterior structural ribs. We help you match diameter, coating, and installation requirements to your project.

Enhance Your Storm Sewer System with ULTRA FLO®.
0.012
Manning’s n
<10%
Weight of comparable RCP
18–120″
Diameter range
20–40 ft
Section lengths
Site-specific
Coating and service-life selection

The low-cost alternative to concrete pipe.

The storm sewer system thatbeats concrete and plastic – on their own terms.

One wall. Two functions.

Smooth where it flows.
Ribbed where it's loaded.

The spiral rib profile combines a smooth interior for hydraulic performance with exterior box ribs for structural strength. Select pipe gage and cover limits using project-specific design requirements.

Smooth interior bore

Manning's n = 0.012 — the same hydraulic efficiency as reinforced concrete and smooth-wall plastic, so a smaller pipe often carries the same flow.

Exterior box ribs

The 3/4″ rib profile delivers structural strength shown to be equivalent to RCP — with heights of cover that exceed both concrete and plastic.

Why specify ULTRA FLO

Three things no other
storm sewer pipe does at once.

FLOW

Smooth interior hydraulics

Design around a smooth bore and shop-fabricated fittings.

  • Manning’s n of 0.012, matched to RCP
  • Curvilinear alignment around obstacles
  • Tees, wyes, elbows, manifolds shop-fabricated
STRENGTH

Flexible pipe design

A flexible steel system that carries load and moves with the soil — instead of cracking in settlement and poor ground.

  • Heights of cover greater than RCP or plastic
  • Flexes with settlement and soft ground
  • ASTM A760 / AASHTO M36
SPEED

A tenth of the weight to install

Longer lengths and QUICK STAB® joints mean fewer joints, lighter equipment, and a lower number at the bottom of the bid.

  • Under 10% the weight of RCP (aluminum: 1/35)
  • 20–40 ft lengths — fewer joints per run
  • QUICK STAB & HUGGER® bands — no special tools
Compare design criteria

The middle that wins both ways.

Storm sewer material design considerations
Criteria Reinforced concrete ULTRA FLO® Plastic, HDPE/PP
Hydraulic efficiency (Manning's n) 0.012 0.012 – equal ~0.012
Handling weight Heaviest Under 10% of comparable RCP Light
Height of cover   High Greater than RCP or plastic Limited
Behavior in poor/settling soil Rigid — cracks Flexes & adapts Flexes
Standard length / joint count Short — many joints 20–40 ft — fewer joints Moderate
Service life (proper coating) Long 75–100+ years Long

Compare equivalent diameters, design loads, installation conditions, and applicable specifications. Consult the linked Contech comparison literature for product-specific details.

Built for the schedule

Fewer joints.
Faster trench.

Over a 240-ft storm sewer run, longer ULTRA FLO sections mean far fewer joints to make in the field — less time in the trench, less equipment, less risk..

  • No special tools or skills to join
  • Lighter pipe, smaller placement equipment
  • Shop-fabricated fittings drop in clean
  • Flexible system forgives imperfect bedding.

How can I avoid expensive long lead time
junction boxes?

ULTRA FLO® 40 ft sections5 internal joints

240 ft ÷ 40 ft = 6 sections

RCP 8 ft sections29 internal joints

240 ft ÷ 8 ft = 30 sections

Illustrative comparison using the stated section lengths. End connections are excluded; supplied lengths and site conditions vary.

Match the coating to the ground

One pipe. A service life for every site.

Standard

Galvanized

A zinc coating option for corrugated steel. The most economical metallic coating for corrugated steel.

 
75+ Year

Aluminized Type 2

Hot-dipped in pure aluminum for maintenance-free service life.

 
75+ Year

CORLIX®

Predictable life in corrosive environments and municipal sewers. .

 
100+ Year

Polymer-coated

Heavy-gage polymer protects against abrasion and corrosion.

 

 

Service life depends on site exposure, abrasion, soil and water chemistry, material, coating, and maintenance. Confirm project-specific selection with Contech.

ULTRA FLO project questions

How do I choose the diameter and coating?

Start with your design flow, slope, cover, loading, and soil and water conditions. We can help you review pipe sizing and material or coating options against those inputs. Confirm the final selection against the applicable specifications and the current Contech product literature.

How many joints are needed for a 240-ft run?

Using 40-ft sections, a straight 240-ft run contains six sections and five internal joints. Using 8-ft sections, the same run contains thirty sections and twenty-nine internal joints. These counts exclude end connections, fittings, and other changes in alignment; actual supplied lengths may vary.

Where can I find specifications and comparison literature?

Use the technical-document links in the design-tools section to review the ULTRA FLO brochure, comparison fliers, and CMP Design Guide. Check the edition and applicability before specifying. Your local Contech contact can help identify documents relevant to your material, coating, loading, and installation conditions.

What information should I send for project pricing?

Share the proposed alignment, pipe diameters, quantities, cover, loading, fittings, joint requirements, and material or coating preferences. Include drawings and known site conditions where available. Use the request-pricing or start-a-project links to begin the discussion; our team can help identify any additional design information needed.

Design and specify

Put ULTRA FLO on your plans

 

Sizing & hydraulics

Review design flow, diameter, gage, and coating with Contech engineering support.

Start a project →
 

Specifications & standards

Access product literature and the CMP Design Guide for your specification review.

Technical documents →
 

Head-to-head comparisons

Review ULTRA FLO comparison literature alongside your project’s design requirements.

Get the comparisons →

*Product specifications shown above are supplied in the design brief. Confirm current sizes, lengths, weights, joints, and availability in the product literature before specification.

From concept to installation

Engineering support for your storm sewer design

Design review

Discuss site conditions and product selection with our team.

Hydraulic calculations

Review flow requirements, pipe sizing, and hydraulic performance.

Structural requirements

Evaluate cover, loading, and foundation considerations.

Project estimates

Request pricing for your proposed system.

Design coordination

Discuss drawings and submittal needs for your project.

On-site assistance

Coordinate preconstruction meetings, delivery, and installation support.

Consider ULTRA FLO® for your next storm sewer

Share your design flow, cover, alignment, and site conditions. We’ll help you evaluate pipe sizing, coating options, and project pricing.

Request a Quote!

Contech Engineered Solutions

Contech® Engineered Solutions · Manufacturing America's Infrastructure™

www.conteches.com